Origins & Mission

A Father's Empathy, A CTO's Execution

Pioneering active, ungrounded neurorehabilitation for pediatric hypotonia—replacing rigid mechanical immobilization with responsive kinesthetic cueing.

Founder Story Graphic

The Personal Origin: Alwin's Diagnosis

When my son Alwin was diagnosed with Charcot-Marie-Tooth Type 1B (CMT1B), our family faced a daunting neurological reality: a mutation in the myelin protein zero (MPZ) gene that slows peripheral nerve conduction velocity to under 15 m/s, producing a severe 200 ms sensorimotor reflex latency and generalized muscular hypotonia.

Standard clinical orthotics offered only static, rigid plastic corsets and standing frames. While these hold a fragile child artificially upright, they bypass the child's muscular system entirely, causing progressive paraspinal disuse atrophy and sensory learned non-use.

Observing hands-on Dynamic Movement Intervention (DMI) therapy sessions revealed a transformative alternative: children with hypotonia do not need rigid external scaffolding—they need sub-maximal, precisely timed tactile prompts at distal key points. That insight became Active Kinesthetic Cueing (BalanceImpulse): providing ungrounded micro-second torque bursts (<1.5 Nm) that awaken the child's own postural righting reflexes.

Founder Journey

From Living Room Insight to MedTech Rigor

Read the unabridged story of how parental dedication, first-principles physics ($T = I \cdot \alpha$), and automated multi-agent engineering transformed an urgent family need into a validated pediatric medical platform.

Key Biomechanical Invariants
  • CMT1B 200 ms Sensorimotor Reflex Delay Compensation
  • ≤ 1.5 Nm Pediatric Torque Ceiling (Zero Startle Shock)
  • 100% Ungrounded Reaction Momentum (No Rigid Bracing)
Dual-Brand Architecture & Trajectory

Balance Bionics & Mitti: The 10-Year Platform

We cleanly decouple our 10-year deep-tech corporate platform from our compassionate pediatric product line.

Balance BionicsCorporate Umbrella

The Deep-Tech & IP Platform

Balance Bionics is our European deep-tech holding and intellectual property vehicle. It houses our 5 patent candidate filings [IP-SCHUTZ: 1–5], our non-dilutive grant applications (BMBF KMU-innovativ, ZIM, SPRIND, EIC Accelerator), and our 10-year technology-agnostic roadmap scaling ungrounded momentum exchange into adult neurorehabilitation, gait stabilization, and industrial assistive robotics.

  • ✓Proprietary reaction-wheel momentum exchange IP portfolio
  • ✓Non-dilutive deep-tech funding strategy (TRL 3 to TRL 6)
  • ✓Universal architecture for pediatric and adult neuro-recovery
Balance BionicsMitti
Pediatric Line

The Pediatric Assistive Wearable

Mitti is our flagship pediatric product brand—engineered with deep parental care for children with muscular hypotonia and peripheral demyelinating neuropathies. Designed as a soft, non-stigmatizing pelvic wearable (<250g capsule), Mitti preserves full body freedom while providing sub-maximal Active Kinesthetic Cueing to stimulate neuroplasticity.

  • ✓Pediatric safety envelope: ≤ 1.5 Nm torque, < 50°C thermal limit
  • ✓CE MDR Class I/IIa medical device compliance pathway
  • ✓Ergonomic magnetic quick-release harness with zero fear factor
Balance Bionics and Mitti 3-Horizon Platform Trajectory
Illustrative AI visualization — not the final device
Phase 1Pre-Project2025 – Early 2026
Completed

Genesis & Active Kinesthetic Cueing

Observing hands-on DMI physical therapy sessions led to a foundational breakthrough: children with hypotonia don't need heavy, rigid exoskeletons — they need gentle, micro-second tactile cues to awaken their own postural reflexes.

Key Deliverables & Milestones

  • Formulation of the ungrounded reaction wheel stabilization concept (T = I · α)
  • Initial 3D CAD kinematic packaging and modular harness ergonomics
  • Establishment of the 12-persona multi-disciplinary AI engineering team
Target Torque: <1.5 Nm sub-maximal promptTarget Actuator Weight: <150g per module100% ungrounded reaction torque
Phase 2Horizon 1Mid 2026
Completed

MuJoCo SITL Simulation & Physics Validation

Before physical fabrication, we constructed rigorous multi-body physics simulations in MuJoCo SITL to validate that ungrounded reaction wheels can effectively stabilize pediatric inverted pendulum dynamics within motor electromagnetic saturation limits.

Key Deliverables & Milestones

  • Multi-body pediatric biomechanics model with realistic hypotonic compliance
  • Electromagnetic motor saturation and inertia sweep verification (Gate 1 sign-off)
  • 3-stage graduated failsafe simulation with zero recoil whiplash
Gate 1 Physical Feasibility: Passed100+ automated Monte Carlo parameter sweepsTorque saturation ceiling confirmed within BLDC envelope
Phase 3Horizon 1Late 2026 (Active)
Active Proving Ground

Heavy Mode Proving Ground & Testbed

Hardware-in-the-Loop bench validation using high-power ODrive D6374 150KV / Maxon EC90 motors, ODrive FOC controllers, and non-blocking ESP32 firmware loops to stress-test real-world dynamic response, thermal limits, and failsafe timing.

Key Deliverables & Milestones

  • ODrive D6374 / Maxon EC90 + ODrive physical test bench verification
  • Deterministic non-blocking ESP32 firmware (<1ms loop latency, zero delay())
  • Pediatric 1.5 Nm torque governor and <50°C thermal envelope validation
Gate 2 Medical Safety: Active validationESP-NOW master-to-actuator latency: <10ms3-Stage failsafe: 200ms coast / 500ms brake / 1000ms kill
Phase 4Horizon 22027 & Beyond
Planned Horizon

Clinical Trials & CE/MDR Certification

Transition from laboratory proving ground to supervised clinical pilot trials in pediatric therapy centers, accompanied by full EU MDR 2017/745 Class I/IIa regulatory documentation.

Key Deliverables & Milestones

  • ISO 14971 Risk Management & IEC 62304 Software Lifecycle Technical Files
  • Multi-center clinical pilot evaluation with certified DMI physiotherapists
  • Miniaturized <150g wearable hip module with magnetic Poka-Yoke quick-connect harness
Gate 3 Clinical & Gate 4 Usability Sign-offsEU MDR 2017/745 conformity clearanceLongitudinal pediatric trunk stability improvement metrics
Engineering Operating Model

The "1 + AI" Multidisciplinary Factory

Mitti operates on a hybrid engineering model: human paternal direction (P0: CTO Dad) paired with 11 domain-specialized AI personas (P1–P11) governed by 4 non-negotiable Decision Gates.

The 4 Non-Negotiable Decision Gates

Formal Quality Governance
Gate 1Gatekeeper: P4

Physical Feasibility

First-principles verification of torque generation and motor physics.

Verified in MuJoCo SITL; torque T = I · α within motor EM saturation.
Gate 2Gatekeeper: P5, P6

Medical & Thermal Safety

Pediatric physiological protection and fail-safe operation.

Max torque <1.5 Nm; motor surface temp <50°C; 3-stage failsafe (200ms/500ms/1000ms) verified.
Gate 3Gatekeeper: P7, P8, P9, P10

Clinical Benefit

Active motor learning and spinal symmetry protection.

Assist-as-Needed profile active; fatigue telemetry enabled; no passive bracing.
Gate 4Gatekeeper: P0, P11

Alwin Usability

Child and family user experience, ergonomics, and Poka-Yoke safety.

Weight <150g per module; quick-release mounting; zero discomfort or fear factor.

Persona Registry (P0–P11)

12 Specializations Active
P0Leadership & Product
Gate 4: Alwin Usability

Product Owner (CTO Dad)

Vision, Prioritization & Ultimate Decision Authority

Domain Scope: Entire System Architecture & Real-World Utility
Core Directive

"Evaluate every concept against real-world benefit for Alwin today. Reject ideas that don't improve mobility or safety — regardless of technical elegance or commercial hype."

Key Invariants & Focus
  • Weight <150g per hip actuator module
  • Zero fear factor or discomfort for pediatric user
  • Prioritizes immediate real-world daily utility
Focus Scope*
P1Engineering

Embedded Software Engineer

Firmware Architecture & Real-Time Protocols

Domain Scope: ESP32/AtomS3 firmware, ESP-NOW protocol, non-blocking loops
Core Directive

"Drive battery-efficient, latency-critical, non-blocking firmware. Zero delay() in loops, zero hot-path heap allocations, thin ISR callbacks."

Key Invariants & Focus
  • ESP-NOW master/slave communication (<10ms broadcast)
  • Stack-only buffer allocations with snprintf
  • Sub-millisecond real-time loop execution
Focus Scopesrc/, lib/, test/
P2Engineering

Mechatronics Engineer

Actuator Hardware, Motors & CAD Design

Domain Scope: BLDC selection, flywheel assemblies, CAD harnesses, PCBA
Core Directive

"Maximize mechanical power density while minimizing weight and size. Iterate on materials and drive concepts for optimal torque transfer."

Key Invariants & Focus
  • Slotless BLDC (Alva STM) & ODrive D6374 / Maxon EC90 Flat integration
  • Parametric CadQuery modular harness mounts
  • 7.5A blade fuse and INA226 power telemetry
Focus Scopemanufacturing/, docs/08_*
P3Engineering

Control Systems Engineer

Sensor Fusion, PID & Postural Filters

Domain Scope: 6-DoF IMU pose estimation, complementary filters, reactive PID
Core Directive

"Develop and implement filters, models, and control loops to translate raw sensor telemetry into therapeutically useful corrective reactions without overshoot."

Key Invariants & Focus
  • Complementary 6-DoF IMU sensor fusion
  • Sawtooth torque shaping with phase-reset
  • Anti-windup PID control with deadband filtering
Focus Scopelib/shared/, src/hub/
P4Physics & Simulation
Gate 1: Physical Feasibility

System Physicist

First-Principles Physics & SITL Simulation

Domain Scope: MuJoCo simulation, motor saturation, physics parameter sweeps
Core Directive

"Challenge every concept on first-principles physical feasibility. Prevent magical thinking by verifying T = I · α against motor electromagnetic limits in MuJoCo."

Key Invariants & Focus
  • MuJoCo multi-body pediatric inverted pendulum model
  • Electromagnetic motor saturation validation
  • Clean SITL parameter sweeps with automated logging
Focus Scopesimulation/, docs/07_*
P5Safety & Regulatory
Gate 2: Medical & Thermal Safety

Safety Engineer

Failsafe Architecture & Hazard Mitigation

Domain Scope: 3-stage failsafe, thermal boundaries, overcurrent protection
Core Directive

"Question every hardware and software concept for potential hazards. Demand absolute fail-safety and redundant cutoffs. Accept zero residual technical risk for pediatric patients."

Key Invariants & Focus
  • 1.5 Nm pediatric torque hard ceiling (2.0 Nm cutoff)
  • Motor surface temperature strictly <50°C
  • 3-stage graduated failsafe (200ms/500ms/1000ms)
Focus ScopeSafety paths in src/, lib/
P6Safety & Regulatory
Gate 2: Medical & Thermal Safety

MDR Regulatory Expert

Medical Device Regulations & Standards Compliance

Domain Scope: EU MDR 2017/745, ISO 14971, IEC 62304, Technical Documentation
Core Directive

"Ensure design decisions, material selection (biocompatibility), and software architecture remain certifiable under EU Medical Device Regulation (MDR 2017/745)."

Key Invariants & Focus
  • ISO 14971 Risk Management compliance
  • IEC 62304 Software Lifecycle governance
  • Biocompatible skin-contact materials classification
Focus Scopedocs/, specs/
P7Clinical Advisory
Gate 3: Clinical Benefit

DMI Physiotherapist

Dynamic Movement Intervention & Challenge Calibration

Domain Scope: Tactile prompt thresholds, therapy mode tuning, CNS challenge
Core Directive

"Continuously seek the 'sweet spot' of maximum challenge. Configure system behavior that intervenes only at the last moment, prompting the patient to self-correct posture."

Key Invariants & Focus
  • Translates DMI tactile facilitation into active kinesthetic cues (BalanceImpulse)
  • Sub-maximal tactile challenge thresholds
  • Distal-to-proximal active trunk core facilitation
Focus ScopeMode configs, docs/01_hub/specs/modes/
P8Clinical Advisory
Gate 3: Clinical Benefit

Mototherapist

Gait Kinematics & Dynamic Muscular Recruitment

Domain Scope: Gait rhythm synchronization, cadence pacing, dithering
Core Directive

"Treat learning to walk as playful sport. Use dynamic, action-rich stimuli to 'wake up' muscular hypotonia and provide an energetic pace-maker for fluid forward motion."

Key Invariants & Focus
  • Asymmetric sawtooth dithering prevents neural adaptation
  • Rhythmic walking metronome synchronization
  • Dynamic cadence pacing for fluid locomotion
Focus ScopeGait mode, dithering logic
P9Clinical Advisory
Gate 3: Clinical Benefit

Kinder-Physiotherapeutin

Pediatric Fatigue & Cardiovascular Protection

Domain Scope: Muscular fatigue telemetry, exhaustion detection, HCM profile
Core Directive

"Monitor cardiovascular and muscular load limits precisely. Demand intelligent logic that recognizes exhaustion patterns and throttles the system before overexertion."

Key Invariants & Focus
  • Continuous fatigue monitoring telemetry for all users
  • Optional HCM (Hypertrophic Cardiomyopathy) soft-mode throttling
  • Overexertion prevention via telemetry thresholds
Focus ScopeFatigue/HCM code paths
P10Clinical Advisory
Gate 3: Clinical Benefit

Pädiatrischer Orthopäde

Spinal Biomechanics & Scoliosis Prevention

Domain Scope: Differential spine-pelvis kinematics, spinal symmetry enforcement
Core Directive

"Evaluate all system impulses and harness concepts strictly for biomechanical impact. Block concepts that could cause asymmetric loading or spinal deformity."

Key Invariants & Focus
  • Dual IMU (thoracic vs. pelvic) differential tracking
  • Spinal symmetry enforcement in 3D planes
  • Eliminates axial compressive loading on pediatric spine
Focus ScopeScoliosis mode, pelvic IMU extension
P11Leadership & Product
Gate 4: Alwin Usability

Ergonomie-Designer

Pediatric UX, Harness Ergonomics & Poka-Yoke Design

Domain Scope: Harness quick-release, display UX, operator error prevention
Core Directive

"Focus on absolutely frictionless, self-explanatory 'plug-and-play' experience. Design physical and digital interaction points so error-resistant (Poka-Yoke) that no manuals are needed."

Key Invariants & Focus
  • Poka-Yoke magnetic quick-release fasteners
  • Self-explanatory AMOLED 1.43" touch interface
  • Ultra-soft, washable pediatric-grade harness lining
Focus ScopeManufacturing, display UI
Single-Home Clinical Architecture

Evidence-Based Pediatric Neuroplasticity

In compliance with our single-home content architecture, the complete biomechanical methodologies (Dynamic Movement Intervention, Vojta Reflex Locomotion, Bobath Tone Regulation, and Assist-as-Needed Control) and our 6 clinical operational modes are maintained centrally on our dedicated clinical portal.

DMI Facilitation

Distal micro-prompts provoke active trunk muscle self-recruitment.

Vojta & Bobath

Automatic postural righting circuits and bilateral spinal symmetry.

Assist-as-Needed

Sawtooth torque dithering prevents sensory neural habituation.

Validation & Verification

Explore Research Preprints & Technical Specs

Access our scientific publications, interactive MuJoCo physics simulation sandbox, and formal safety guarantees.

Academic Preprint

Reaction-Wheel Postural Stabilization

Read our scientific preprint on ungrounded reaction-wheel momentum exchange, CMT1B reflex delay modeling, and Real2Sim SITL verification.

Interactive Physics

MuJoCo Simulation Demo

Test first-principles reaction torque physics ($T = I \cdot \alpha$), parameter sweeps, and inverted pendulum stabilization live in browser.